Copyright (c) 2019, Lars Brubaker, John Lewin
|
|
All rights reserved.
|
|
|
|
Redistribution and use in source and binary forms, with or without
|
|
modification, are permitted provided that the following conditions are met:
|
|
|
|
1. Redistributions of source code must retain the above copyright notice, this
|
|
list of conditions and the following disclaimer.
|
|
2. Redistributions in binary form must reproduce the above copyright notice,
|
|
this list of conditions and the following disclaimer in the documentation
|
|
and/or other materials provided with the distribution.
|
|
|
|
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND
|
|
ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
|
|
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
|
|
DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR
|
|
ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES
|
|
(INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
|
|
LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND
|
|
ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
|
|
(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS
|
|
SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
|
|
|
The views and conclusions contained in the software and documentation are those
|
|
of the authors and should not be interpreted as representing official policies,
|
|
either expressed or implied, of the FreeBSD Project.
|
|
*/
|
|
|
|
using System;
|
|
using MatterHackers.Localizations;
|
|
using MatterHackers.MatterControl.PrinterCommunication;
|
|
using MatterHackers.MatterControl.SlicerConfiguration;
|
|
|
|
namespace MatterHackers.MatterControl.ConfigurationPage.PrintLeveling
|
|
{
|
|
public class CalibrateProbeRemovePaperInstructions : WizardPage
|
|
{
|
|
public CalibrateProbeRemovePaperInstructions(ISetupWizard setupWizard, string headerText, bool lastPage = true)
|
|
: base(setupWizard, headerText, "")
|
|
{
|
|
contentRow.AddChild(
|
|
this.CreateTextField(
|
|
"Manual Z Calibration complete.".Localize() +
|
|
"\n • " +
|
|
"Remove the paper".Localize()));
|
|
|
|
contentRow.BackgroundColor = theme.MinimalShade;
|
|
|
|
if (lastPage)
|
|
{
|
|
this.ShowWizardFinished();
|
|
}
|
|
}
|
|
|
|
public override void OnLoad(EventArgs args)
|
|
{
|
|
printer.Connection.QueueLine("T0");
|
|
printer.Connection.MoveRelative(PrinterConnection.Axis.X, .1, printer.Settings.Helpers.ManualMovementSpeeds().X);
|
|
|
|
if (printer.Settings.GetValue<bool>(SettingsKey.z_homes_to_max))
|
|
{
|
|
printer.Connection.HomeAxis(PrinterConnection.Axis.XYZ);
|
|
}
|
|
else if (!printer.Settings.GetValue<bool>(SettingsKey.has_z_probe))
|
|
{
|
|
// Lift the hotend off the bed - at the conclusion of the wizard, make sure we lift the heated nozzle off the bed
|
|
printer.Connection.MoveRelative(PrinterConnection.Axis.Z, 30, printer.Settings.Helpers.ManualMovementSpeeds().Z);
|
|
}
|
|
|
|
base.OnLoad(args);
|
|
}
|
|
}
|
|
|
|
public class ConductiveProbeCalibrateComplete : WizardPage
|
|
{
|
|
public ConductiveProbeCalibrateComplete(PrinterConfig printer, ISetupWizard setupWizard, string headerText)
|
|
: base(setupWizard, headerText, "")
|
|
{
|
|
var completedText = "Conductive Z Calibration complete.".Localize();
|
|
if (printer.Settings.GetBool(SettingsKey.has_swappable_bed))
|
|
{
|
|
completedText += "\n\n • " + "Place the bed back on the printer".Localize();
|
|
}
|
|
|
|
completedText += "\n\n" + "Click 'Done'".Localize();
|
|
|
|
contentRow.AddChild(this.CreateTextField(completedText));
|
|
|
|
contentRow.BackgroundColor = theme.MinimalShade;
|
|
|
|
this.ShowWizardFinished();
|
|
}
|
|
|
|
public override void OnLoad(EventArgs args)
|
|
{
|
|
printer.Connection.QueueLine("T0");
|
|
printer.Connection.MoveRelative(PrinterConnection.Axis.X, .1, printer.Settings.Helpers.ManualMovementSpeeds().X);
|
|
|
|
if (printer.Settings.GetValue<bool>(SettingsKey.z_homes_to_max))
|
|
{
|
|
printer.Connection.HomeAxis(PrinterConnection.Axis.XYZ);
|
|
}
|
|
else if (!printer.Settings.GetValue<bool>(SettingsKey.has_z_probe))
|
|
{
|
|
// Lift the hotend off the bed - at the conclusion of the wizard, make sure we lift the heated nozzle off the bed
|
|
printer.Connection.MoveRelative(PrinterConnection.Axis.Z, 30, printer.Settings.Helpers.ManualMovementSpeeds().Z);
|
|
}
|
|
|
|
base.OnLoad(args);
|
|
}
|
|
}
|
|
|
|
public class CleanNozzleBeforeConductiveProbe : WizardPage
|
|
{
|
|
public CleanNozzleBeforeConductiveProbe(PrinterConfig printer, ISetupWizard setupWizard, string headerText)
|
|
: base(setupWizard, headerText, "")
|
|
{
|
|
var completedText = "Before Z-Calibration can begin you need to:".Localize();
|
|
if (printer.Settings.GetBool(SettingsKey.has_swappable_bed))
|
|
{
|
|
completedText += "\n\n • " + "Remove the bed from the printer so the nozzle can get low enough to touch the pad".Localize();
|
|
}
|
|
|
|
completedText += "\n • " + "Ensure the nozzle is clear of any debris or filament".Localize();
|
|
completedText += "\n\n" + "Click 'Next' to continue.".Localize();
|
|
|
|
contentRow.AddChild(this.CreateTextField(completedText));
|
|
|
|
contentRow.BackgroundColor = theme.MinimalShade;
|
|
}
|
|
}
|
|
} |