/* Copyright (c) 2018, Lars Brubaker, John Lewin All rights reserved. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer. 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution. THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. The views and conclusions contained in the software and documentation are those of the authors and should not be interpreted as representing official policies, either expressed or implied, of the FreeBSD Project. */ using System; using System.Linq; using MatterHackers.MatterControl.SlicerConfiguration; namespace MatterHackers.MatterControl.ConfigurationPage.PrintLeveling { public static class LevelingValidation { public static bool NeedsToBeRun(PrinterConfig printer) { PrintLevelingData levelingData = printer.Settings.Helpers.GetPrintLevelingData(); var required = printer.Settings.GetValue(SettingsKey.print_leveling_required_to_print); if (required && levelingData == null) { // need but don't have data return true; } var enabled = printer.Settings.GetValue(SettingsKey.print_leveling_enabled); // check if leveling is turned on if (required && !enabled) { // need but not turned on return true; } if (!required && !enabled) { return false; } // check that there are no duplicate points var positionCounts = from x in levelingData.SampledPositions group x by x into g let count = g.Count() orderby count descending select new { Value = g.Key, Count = count }; foreach (var x in positionCounts) { if (x.Count > 1) { return true; } } // check that the solution last measured is the currently selected solution if (printer.Settings.GetValue(SettingsKey.print_leveling_solution) != levelingData.LevelingSystem) { return true; } // check that the bed temperature at probe time was close enough to the current print bed temp double requiredLevelingTemp = printer.Settings.GetValue(SettingsKey.has_heated_bed) ? printer.Settings.GetValue(SettingsKey.bed_temperature) : 0; // check that the number of points sampled is correct for the solution switch (levelingData.LevelingSystem) { case LevelingSystem.Probe3Points: if (levelingData.SampledPositions.Count != 3) // different criteria for what is not initialized { return true; } break; case LevelingSystem.Probe7PointRadial: if (levelingData.SampledPositions.Count != 7) // different criteria for what is not initialized { return true; } break; case LevelingSystem.Probe13PointRadial: if (levelingData.SampledPositions.Count != 13) // different criteria for what is not initialized { return true; } break; case LevelingSystem.Probe100PointRadial: if (levelingData.SampledPositions.Count != 100) // different criteria for what is not initialized { return true; } break; case LevelingSystem.Probe3x3Mesh: if (levelingData.SampledPositions.Count != 9) // different criteria for what is not initialized { return true; } break; case LevelingSystem.Probe5x5Mesh: if (levelingData.SampledPositions.Count != 25) // different criteria for what is not initialized { return true; } break; case LevelingSystem.Probe10x10Mesh: if (levelingData.SampledPositions.Count != 100) // different criteria for what is not initialized { return true; } break; case LevelingSystem.ProbeCustom: if (levelingData.SampledPositions.Count != LevelWizardCustom.ParseLevelingSamplePoints(printer).Count) { return true; } break; default: throw new NotImplementedException(); } return false; } } }