make sure we return to correct temp on tool change
issue: MatterHackers/MCCentral#5223 Temperature progressively drops during dual extrusion prints.
This commit is contained in:
parent
714c2a1dfa
commit
4320ed954c
3 changed files with 7 additions and 4 deletions
|
|
@ -100,7 +100,10 @@ namespace MatterHackers.MatterControl.PrinterCommunication.Io
|
|||
// check if this command contains a tool specification
|
||||
GCodeFile.GetFirstNumberAfter("T", lineToSend, ref requestedToolForTempChange);
|
||||
|
||||
targetTemps[requestedToolForTempChange] = toolTemp;
|
||||
if (!lineToSend.Contains("; INACTIVE_COOL_DOWN"))
|
||||
{
|
||||
targetTemps[requestedToolForTempChange] = toolTemp;
|
||||
}
|
||||
}
|
||||
|
||||
// check if any of the heaters we will be switching to need to start heating
|
||||
|
|
@ -264,7 +267,7 @@ namespace MatterHackers.MatterControl.PrinterCommunication.Io
|
|||
targetTemp = Math.Max(0, targetTemp - printer.Settings.GetValue<double>(SettingsKey.inactive_cool_down));
|
||||
if (targetTemp != printer.Connection.GetTargetHotendTemperature(activeTool))
|
||||
{
|
||||
gcode.AppendLine($"M104 T{activeTool} S{targetTemp}");
|
||||
gcode.AppendLine($"M104 T{activeTool} S{targetTemp} ; INACTIVE_COOL_DOWN");
|
||||
}
|
||||
}
|
||||
}
|
||||
|
|
|
|||